Report: Britain Begins Sheltering Fighter Jets in Hardened Hangars Amid Drone Attack Threats

The UK Royal Air Force moves combat aircraft into hangars and hardened shelters overnight to protect them from potential drone attacks.
Sky News reported this.
In addition, the Royal Air Force plans to use simpler and more affordable protective measures.
These include anti-drone nets, which are widely used in Ukraine to protect military equipment, critical infrastructure facilities and key roads from Russian drones.
They are intended to prevent drones from directly hitting aircraft and, when combined with other protective structures, reduce the risk of damage from debris.
In parallel, the British Royal Air Force is practising dispersing its aircraft across different airfields. The RAF’s Chief of the Air Staff, Air Chief Marshal Sir Harv Smyth, stated that British forces are preparing for a scenario in which no airbase in the country can be guaranteed protection from attacks.
According to him, during runway repairs at Brize Norton in the summer, the RAF dispersed its aircraft between Prestwick airbase in Scotland and Boscombe Down airfield in England.
Hardened Shelters
It is worth noting that the UK has a well-developed system of protective shelters for aircraft. During the Cold War, the Royal Air Force took into account the possibility of Soviet ballistic and cruise missile strikes against British airfields.
As a result, full-fledged reinforced concrete shelters for fighter aircraft were built at airbases.
Despite the presence of these structures, they could not provide full protection for the entire aircraft fleet. As a result, some aircraft had to be dispersed or stationed at reserve airfields.
In the 1960s–1980s, the Royal Air Force developed specialised quick-reaction alert hangars known as QRA sheds or Q-sheds. These structures were built at air defence bases where Lightning fighters, and later Phantoms, were on standby. Examples include RAF Leuchars, RAF Binbrook and RAF Wattisham.
Q-sheds featured a steel frame and typically consisted of two adjacent bays for housing two fully fuelled and armed fighter jets. A brick staff building was attached to the main structure, while residential trailers for the crews on duty were set up nearby. The entire site was enclosed by a barbed-wire fence.
These hangars were not bomb-resistant and did not provide full protection against missile strikes. Their primary purpose was to shield aircraft from the weather and enable rapid take-offs. Crews could get the fighters airborne in approximately 10 minutes. The transition to large-scale construction of Hardened Aircraft Shelters (HAS) took place in the late 1960s and early 1970s.
The 1967 Six-Day War was an important catalyst. During Israel’s pre-emptive strike on Arab airbases, a large number of aircraft parked in the open were destroyed. This experience demonstrated the vulnerability of aircraft on the ground and the need to build hardened structures to protect them.
NATO initially focused on fortifying forward airbases in West Germany. In particular, the construction of HAS and the structures concealment at British RAF Germany bases in Brüggen, Laarbruch, Wildenrath and Gütersloh began in 1974. However, some experimental designs had appeared even earlier, including at Wildenrath in 1954.
The UK approved its own airfield protection programme in November 1974 and July 1975. However, financial constraints significantly slowed its implementation. In March 1979, the British air defence system still did not have a single reinforced concrete shelter for fighter aircraft.
Design of British HAS
Unlike the early hardened shelters used by NATO countries, such as the German TAB-Vs, which measured approximately 14.6 × 30.7 metres and were designed to withstand a direct hit from a 226 kg aerial bomb, the UK used several types of standardised shelters.
In total, three main types of HAS, along with several specialised designs, were built at British airfields.
The largest standard variant was the Type 1. It measured 37.8 metres in length, had a floor width of 25 metres and stood 10 metres tall.
The entrance was fitted with two massive reinforced concrete doors running on steel rails. Each door leaf weighed approximately 85 tonnes. Ten U-shaped tubular ventilation ducts ran along the roof ridge. A blast-resistant personnel entrance was built on the left, while a central concrete gas exhaust duct was installed at the rear.
The second type of HAS was smaller, measuring approximately 36.6 × 21.6 metres. Its distinctive feature was two wing-shaped gas exhaust ducts angled upwards. Such structures can be found at Boscombe Down, Lakenheath and Upper Heyford airbases.
The third type of shelter, known as the Phase 3 HAS, became the most widely used by the Royal Air Force. These structures were built at RAF Coningsby, Honington, Marham, Wattisham, Leeming, Leuchars, Lossiemouth and St Mawgan.
The structure was made of reinforced concrete approximately 0.9 metres thick. Additional rooms for aircraft servicing were provided inside, including an annex for a refuelling unit and ground support equipment. The shelter also featured a soundproof booth for crew training.
The Phase 3 HAS could accommodate two Tornado fighters with their wings folded or provide maintenance space for a single aircraft. In particular, 22 additional shelters for Tornado F3 fighters were built at RAF Leeming and RAF Leuchars.